Shear strength tests on geosynthetic liner systems

In order to follow the behaviour of a liner system on the slope, it was decided to carry out a real scale experimentation at Montreuil/Barse (France). Three different systems are tested on the slope 1/1 and 1/2 of one landfill cell. The different components of the liner system are instrumented for displacement measuring. At the same time a laboratory program is carried out to evaluate the shear strength of the materials and their interfaces. The obtained characteristics are used to determine the theoretical stability of the different systems by limit equilibrium methods. The collected data, compared to predicted stability, constitute an efficient way to validate these design methods. / Afin de pouvoir observer le comportement d'un dispositif d'étanchéité en pente, une expérimentation en vraie grandeur a été décidée à Montreuil-sur-Barse (France). Trois dispositifs différents ont été testés sur la pente 1/1 et 1/2 d'une cellule de décharge. Les différents composants du dispositif ont été instrumentés pour la mesure du déplacement. Parallèlement, un programme de laboratoire est mené pour évaluer la résistance au cisaillement des matériaux et de leurs interfaces. Les caractéristiques obtenues sont utilisées pour la détermination de la stabilité théorique des différents dispositifs par les méthodes d'équilibre-limite. Les données recueillies, comparées à la stabilité calculée, constituent un moyen efficace de valider ces méthodes de conception.